beautypg.com

VEGA VEGACAL 67 For connection to a signal conditioning instrument User Manual

Page 30

background image

30

9 Supplement

VEGACAL 67 • For connection to a signal conditioning instrument

31761-EN-130917

1000

750

500

250

12

18

16

14

20

22

24

26

28

30

32

34

36

V

3

1

2

Fig. 15: Voltage diagram
1 Voltage limit EEx-ia instrument

2 Voltage limit non-Ex/Ex-d instrument

3 Operating voltage

Operating voltage with illuminated display and adjustment module

Ʋ Non-Ex instrument

20 … 36 V DC

Ʋ EEx-ia instrument

20 … 30 V DC

Ʋ EEx-d-ia instrument

20 … 36 V DC

Permissible residual ripple

Ʋ < 100 Hz

U

ss

< 1 V

Ʋ 100 Hz … 10 kHz

U

ss

< 10 mV

Load

see diagram

Electrical protective measures
Protection, depending on housing version

Ʋ Plastic housing

IP 66/IP 67

Ʋ Aluminium housing, stainless steel

housing - investment casting, stain-

less steel housing - electro-polished

IP 66/IP 68 (0.2 bar)

3)

Ʋ Aluminium and stainless housing, in-

vestment casting (optionally available)

IP 66/IP 68 (1 bar)

Overvoltage category

III

Protection class

II

3)

A suitable cable is the prerequisite for maintaining the protection rating.