Ambient conditions
A
mbient, storage and transport temperature
-40 … +70 °C (-40 … +158 °F)
Process conditions
P
rocess pressure
-1 … +40
bar/-100 … +4000 kPa (-
-14.5 … +580
psig), depending on the process
fi
tting
P
rocess temperature (thread or flange temperature)
-
FKM (V
iton)
-40 … +150 °C (-40 … +302 °F)
-
EPDM
-40 … +150 °C (-40 … +302 °F)
-
FFKM (K
alrez 6375)
-20 … +150 °C (-4 … +302 °F)
T
he measurement error from the process condi-
tions is in the specified pressure and temperature
range of below 1 %.
0 °C
(32 °F)
40 °C
(104 °F)
20 °C
(58 °F)
60 °C
(140 °F)
80 °C
(176 °F)
50 °C
(122 °F)
-40 °C
(-40 °F)
100 °C
(212 °F)
150 °C
(302 °F)
1
2
Fig. 30: Ambient temperature - Process temperature
1
Ambient temperature
2
Process temperature (depending on the seal material)
Electromechanical data - version IP 66/IP 67
C
able entry
-
D
ouble chamber housing
l
1
x cable gland M20 x 1.5 (cable: ø 5 … 9 mm),
1
x blind stopper M20 x 1.5; plug M12 x 1 for
VEGADIS
61 (
optional)
or:
l
1
x closing cap ½ NPT, 1 x blind stopper
½ NPT
,
plug M12 x 1 for VEGADIS 61
(
optional)
or:
l
1
x plug (depending on the version), 1 x blind
stopper M20 x 1.5; plug M12 x 1 for VEGADIS
61 (
optional)
VEGAFLEX
62 • 4 … 20
mA/HART four-wire