It is designed for industrial use in all areas of process
technology and can be used in non-conductive liquids.
High frequency microwave pulses are guided along a steel
rope or a rod. Upon reaching the product surface, the
microwave pulses are reflected. The running time is evaluated
by the instrument and outputted as distance.
Power is supplied via the H1 Fieldbus. A two-wire cable
according to Fieldbus specification serves as carrier of both
power and digital data for multiple sensors. This cable can be
operated in two versions:
l
via an H1 interface card in the control system and
additional power supply
l
via a Linking device with HSE (High speed Ethernet) and
additional power supply according to IEC 61158-2
The DD (Device Descriptions) and CFF (capability files)
necessary for planning and configuration of your FF (Founda-
tion Fieldbus) communication network are available in the
download area of the VEGA homepage www.vega.com under
"S
ervices - Downloads - Software - Foundation Fieldbus". The
appropriate certificates are also available there. A CD with the
appropriate files and certificates can be ordered via e-mail
under [email protected] or by phone from one of the VEGA
agencies under the order number "DRIVER.S".
The optional heating requires its own power supply. You can
find further details in the supplementary instructions manual
"H
eating for indicating and adjustment module".
3.3 Operation
VEGAFLEX
66 can be adjusted with different adjustment
media:
l
with indicating and adjustment module
l
with the suitable VEGA DTM in conjunction with an
adjustment software according to the FDT/DTM standard,
e.g. PACTware and PC
l
a configuration tool
The entered parameters are generally saved in VEGAFLEX
66, optionally also in the indicating and adjustment module or
in PACTware.
Functional principle
Power supply and bus
communication
DD/CFF
10
VEGAFLEX
66 • Foundation Fieldbus
3 Product description