6 set up, 1 general, 2 adjustment elements – VEGA VEGAKON 66 with transistor output User Manual
Page 14: 6 s et up, Dil switch for mode adjustment, Dil switch for adjustment of the integration time
6 S
et up
6
.1 General
On the electronics module you will find the following indicating
and adjustment elements:
l
DIL switch for mode adjustment
l
DIL switch for adjustment of the integration time
l
Rotary switch for adjustment of the conductivity value
l
Control lamp for indication of the switching condition
6
.2 Adjustment elements
KON E66T
FUNCTION
1 2 3 4 PNP
+
-
1 2 3 4 NPN
+
-
I out
max.400mA
10...55VDC
+
-
3
4
1
2
max
min
K
TEST
0.1
TEST
300
100
30
0.3
1
3
10
A
2s
6s
12s
B
off
off
off
R
1
2
7
6
3
4
5
1
Screwed terminals
2
Signal lamp (LED)
3
Rotary switch: Adjustment of the conductivity value
4
Selection switch: Integration time
5
Selection switch: Mode (A/B) VEGAKON 66
6
Type label
7
Tensile proving ring
The switching condition of the signal lamp can be checked
when the housing is closed. To adjust VEGAKON 66 loosen
the four screws with a wrench on the upper side of the
instrument and remove the housing cover.
Function/Configuration
Signal lamp (2)
14
VEGAKON
66 - with transistor output
Set up
32650
-EN
-070615
- VEGABAR 25 (24 pages)
- VEGAFLEX 55K (32 pages)
- VEGABAR 17 (36 pages)
- D80 Hydrostatic pressure transmitters (40 pages)
- VEGAMET 513 (52 pages)
- D81 Hydrostatic pressure transmitter (44 pages)
- VEGASTAB 690 (12 pages)
- VEGASWING 83 fail safe and signal conditioning instrument VEGATOR 526 Ex (28 pages)
- VEGACONNECT 2 (4 pages)
- D81 METEC Hydrostatic pressure transmitter (44 pages)
- VEGAPULS 45 4 … 20 mA; HART compact sensor (72 pages)
- VEGAMET 515 (68 pages)
- VEGAFLEX 52K (32 pages)
- Capacitive electrodes EK Profibus PA (56 pages)
- VEGATOR 631 S1 (4 pages)
- VEGAPULS 63 (≥ 2.0.0 - ≤ 3.8) 4 … 20 mA_HART - two-wire (68 pages)
- Capacitive electrodes EK 4 … 20 mA - Compact (40 pages)
- VEGABAR 65 4 … 20 mA_HART (76 pages)
- VEGABAR 64 Profibus PA (80 pages)
- VEGABAR 44 4 … 20 mA (28 pages)
- VEGADIS 50 Ex (8 pages)
- VEGAPULS 51V…54V (96 pages)
- VEGAFLEX 54P (Profibus PA) (48 pages)
- VEGASEL 643 (16 pages)
- VEGAPULS 56K (68 pages)
- VEGAFLEX 54K (36 pages)
- VEGABAR 41 HART (44 pages)
- VEGATOR 537 Ex (16 pages)
- VEGACAP 82-98 (36 pages)
- VEGADIS 371 Ex (20 pages)
- Capacitive electrodes EL Profibus PA (56 pages)
- VEGAFLEX 52V (36 pages)
- VEGAFLEX 51K (32 pages)
- VEGALOG 571 EP (Ex) (32 pages)
- D84 Hydrostatic pressure transmitter (44 pages)
- VEGABAR 64 Foundation Fieldbus (80 pages)
- VEGABAR 61 4 … 20 mA_HART (80 pages)
- VEGASCAN 850 (92 pages)
- VEGASON 54P…56P Profibus PA (68 pages)
- D77 Hydrostatic pressure transmitters (24 pages)
- VEGATRENN 546 Safety barrier type 146 (8 pages)
- VEGASON 71 - 1 … 75 - 1 (52 pages)
- VEGABAR 40 HART (40 pages)
- Capacitive electrodes EL … (44 pages)
- VEGABAR 24 (28 pages)