beautypg.com

2 principle of operation, 3 operation, 4 packaging, transport and storage – VEGA VEGAFLEX 66 (-200…+400°C) 4 … 20 mA_HART four-wire User Manual

Page 9

background image

3

.2 Principle of operation

VEGAFLEX

66

is a level sensor with coax, rod or cable probe for

continuous level measurement in products with temperatures between
-

200 °C

and +400 °C (-328 … +752 °F).

I

t is designed for industrial use in all areas of process technology and

can be used in liquids.

H

igh frequency microwave pulses are guided along a steel rope or a

rod. Upon reaching the product surface, the microwave pulses are
reflected. The running time is evaluated by the instrument and
outputted as distance.

F

our-wire electronics with separate power supply.

T

he supply voltage range can differ depending on the instrument

version.

T

he data for power supply are specified in chapter "Technical data".

M

easured value transmission is carried out via the 4 … 20 mA/HART

output separate from power supply.

T

he background lighting of the indicating and adjustment module is

powered by the sensor. A certain level of operating voltage is required
for this. You can find the exact voltage specifications in chapter
"T

echnical data".

3

.3 Operation

VEGAFLEX

66

can be adjusted with different adjustment media:

l

with indicating and adjustment module

l

with the suitable VEGA DTM in conjunction with an adjustment
software according to the FDT/DTM standard, e.g. PACTware and
PC

l

with manufacturer-specific adjustment programs AMS™ or PDM

l

W

ith a HART handheld

3

.4 Packaging, transport and storage

Y

our instrument was protected by packaging during transport. Its

capacity to handle normal loads during transport is assured by a test
according to DIN EN 24180.

T

he packaging of standard instruments consists of environment-

friendly, recyclable cardboard. For special versions, PE foam or PE foil
is also used. Dispose of the packaging material via specialised
recycling companies.

T

ransport must be carried out under consideration of the notes on the

transport packaging. Nonobservance of these instructions can cause
damage to the device.

Application area

Functional principle

Voltage supply

Packaging

Transport

VEGAFLEX

66 • 4 … 20

mA/HART four-wire

9

3 P

roduct description

34174

-

EN

-100426