1

Fig. 4: Position of the polarisation plane of VEGAPULS 67

1

Marking bars

Make sure that all parts of the instrument exposed to the process, in
particular the sensor element, process seal and process fitting, are
suitable for the existing process conditions. These include above all
the process pressure, process temperature as well as the chemical
properties of the medium.

You can find the specifications in chapter "Technical data" or on the
type label.

4

.2 Mounting preparation

The radar sensor can be mounted in two different ways:

l

with a mounting strap

l

via a collar or adapter flange.

The mounting strap enables easy mounting on the vessel wall or silo
top. It is suitable for wall, ceiling or boom mounting. Especially in open
vessels, this is a very easy and effective way to align the sensor to the
bulk solid surface.

Suitability for the pro-
cess conditions

Mounting strap

14

VEGAPULS

67 • Foundation Fieldbus

4 Mounting

32941

-EN