VEGA VEGAFLEX 67 (-40…+150°C PFA insulated) 4 … 20 mA_HART two-wire User Manual
Page 51
0 °C
(32 °F)
40 °C
(104 °F)
20 °C
(58 °F)
60 °C
(140 °F)
80 °C
(176 °F)
50 °C
(122 °F)
-40 °C
(-40 °F)
100 °C
(212 °F)
150 °C
(302 °F)
1
2
Fig. 26: Ambient temperature - Process temperature
1
Ambient temperature
2
Process temperature (depending on the seal material)
Electromechanical data - version IP 66/IP 67 and IP 66/IP 68; 0.2 bar
C
able entry/plug
3)
-
S
ingle chamber housing
l
1
x cable gland M20 x 1.5 (cable: ø 5 … 9 mm),
1
x blind stopper M20 x 1.5
or:
l
1
x closing cap M20 x 1.5; 1 x blind stopper
M
20
x 1.5
or:
l
1
x closing cap ½ NPT, 1 x blind plug ½ NPT
or:
l
1
x plug (depending on the version), 1 x blind
stopper M20 x 1.5
-
D
ouble chamber housing
l
1
x cable entry M20 x 1.5 (cable: ø 5 … 9 mm),
1
x blind stopper M20 x 1.5; 1 x blind stopper
M
16
x 1.5 or optionally available with 1 x plug
M
12
x 1 for external indicating and adjustment
unit
or:
l
1
x closing cap ½ NPT, 1 x blind stopper
½ NPT
, 1
x blind stopper M16 x 1.5 or
optionally 1 x plug M12 x 1 for external
indicating and adjustment unit
or:
l
1
x plug (depending on the version), 1 x blind
stopper M20 x 1.5; 1 x blind stopper M16 x 1.5
or optionally available with 1 x plug M12 x 1 for
external indicating and adjustment unit
3)
D
epending on the version M12 x 1, according to DIN 43650, Harting, 7/
8" FF.
VEGAFLEX
67 • 4 … 20
mA/HART - two-wire
51
10 S
upplement
32303
-
EN
-120329