VEGA VEGAFLEX 67 (-40…+150°C PFA insulated) 4 … 20 mA_HART two-wire User Manual
Page 30

T
his function enables reading out parameter adjustment data as well
as writing parameter adjustment data into the sensor via the indicating
and adjustment module. A description of the function is available in the
operating instructions manual "Indicating and adjustment module".
T
he following data are read out or written with this function:
l
M
easured value presentation
l
A
djustment
l
M
edium
l
V
essel form
l
D
amping
l
L
inearisation curve
l
S
ensor-TAG
l
D
isplayed value
l
D
isplay unit
l
S
caling
l
C
urrent output
l
U
nit of measurement
l
L
anguage
l
S
ensitivity
l
D
ielectric figure
T
he following safety-relevant data are not read out or written:
l
HART
mode
l
PIN
l
SIL
l
S
ensor length/Sensor type
l
F
alse signal suppression
C
opy sensor data
C
opy sensor data?
Basic adjustment
I
f the function "Reset" is carried out, the sensor resets the values of the
following menu items to the reset values (see chart):
1)
T
he following values will be reset:
Function
Reset value
M
ax. adjustment
D
istance, upper dead zone
M
in. adjustment - Rod/Coax version
D
istance, supplied sensor length
M
in. adjustment - Cable version
D
istance, lower dead zone
D
amping ti
0
s
L
inearisation
L
inear
S
ensor-TAG
S
ensor
1)
S
ensor-specific basic adjustment.
Copy sensor data
Reset
30
VEGAFLEX
67 • 4 … 20
mA/HART - two-wire
6 S
et up with the indicating and adjustment module PLICSCOM
32303
-EN
-120329