VEGA VEGAFLEX 67 (-40…+150°C PFA insulated) 4 … 20 mA_HART two-wire User Manual
Page 45

-
R
od: ø 10 mm (0.394 in)
approx. 620 g/m (6.7 oz/ft)
-
C
able: ø 4 mm (0.157 in)
approx. 80 g/m (0.86 oz/ft)
-
G
ravity weight
325
g (11.5 oz)
I
nsulation thickness
-
R
od version
2
mm (0.08 in)
-
C
able version
0.75
mm (0.03 in)
O
n the gravity weight and beginning of the cable:
2
mm (0.08 in)
P
robe length L (from seal surface), cannot be shortened
-
R
od: ø 10 mm (0.394 in)
up to 4 m (13.12 ft)
-
T
rimming accuracy - rod
<
1
mm (0.039 in)
-
C
able: ø 4 mm (0.157 in)
up to 32 m (105 ft)
-
T
rimming accuracy - cable
±
0.05 %
L
ateral load - rod: ø 10 mm (0.394 in)
4 N
m (3 lbf ft)
M
ax. tensile load with cable: ø 4 mm
(0.157
in)
2 KN (450
lbf)
Input variable
M
easured variable
L
evel of liquids
M
in. dielectric figure (lower medium)
by 10 higher than the ε
r
of the upper medium
M
in. layer thickness (upper medium)
>
100
mm (3.937 in)
T
he measured value deviates from the actual level
until the min. layer thickness is reached.
M
ax. layer thickness (upper medium)
-
D
ielectric figure (upper medium) 10
6
m (19.69 ft)
-
D
ielectric figure (upper medium) 5
10
m (32.81 in)
-
D
ielectric figure (upper medium) 2
20
m (65.61 in)
M
in. dielectric figure (upper medium) with
rod, cable version
ε
r
>
1.6
VEGAFLEX
67 • 4 … 20
mA/HART - two-wire
45
10 S
upplement
32303
-
EN
-120329