6 Set up with the indicating and
adjustment module PLICSCOM
6.1 Short description
T
he indicating and adjustment module is used for measured
value display, adjustment and diagnosis. It can be mounted in
the following housing versions and instruments:
l
A
ll sensors of the plics
®
instrument family, in the single as
well as in the double chamber housing (optionally in the
electronics or connection compartment)
l
E
xternal indicating and adjustment unit VEGADIS 61
F
rom a hardware version …- 01 or higher of the indicating and
adjustment module as well as of the corresponding sensor, an
integrated backlight can be switched on via the adjustment
menu. The hardware version is stated on the type label of the
indicating and adjustment module or the sensor electronics.
Information:
T
his function is available at a later date for instruments with
S
tEx, WHG or ship approval as well as country-specific
approvals such as those according to FM or CSA.
Note:
Y
ou can find detailed information on the adjustment in the
operating instructions manual "Indicating and adjustment
module".
6.2 Insert indicating and adjustment module
T
he indicating and adjustment module can be inserted into the
sensor and removed again at any time. It is not necessary to
interrupt the power supply.
P
roceed as follows:
1 U
nscrew the housing cover
2 P
lace the indicating and adjustment module in the desired
position on the electronics (you can choose any one of four
different positions - each displaced by 90°)
3 P
ress the indicating and adjustment module onto the
electronics and turn it to the right until it snaps in.
4 S
crew housing cover with inspection window tightly back
on