10 supplement, 1 technical data – VEGA VEGASON 64 Profibus PA User Manual
Page 49
10 Supplement
10.1 Technical data
General data
Materials, wetted parts
-
Flange
PP or Aluminium
-
Swivelling holder, flange
galvanized steel
-
Transducer
PA (1.4301 with StEx)
-
Transducer diaphragm
316Ti
Materials, non-wetted parts
-
Housing
Aluminium die-casting powder coated
-
Seal between housing and housing
cover
Silicone
-
Inspection window in housing cover
Polycarbonate (UL-746-C listed)
-
Ground terminal
316Ti
-
transducer cable with separate version C
and D
PUR (1.1082)
Weight
5)
-
Compact with flange (version A)
5.6 … 10.7 kg (12.3 … 23.6 lbs)
-
Compact with swivelling holder
(version B)
6.9 … 9.7 kg (15.2 … 21.4 lbs)
-
Separate with swivelling holder
(version C)
7.5 … 10.5 kg (16.5 … 23.1 lbs)
-
Separate with threaded fitting (version D)
4.7 … 6.9 kg (10.4 … 15.2 lbs)
Output variable
Output signal
digital output signal, format according to IEEE-754
Sensor address
126 (default setting)
Current value
10 mA, ±0.5 mA
Damping (63 % of the input variable)
0 … 999 s, adjustable
Step response or adjustment time
≤
250 ms (ti: 0 s, 10 … 90 %)
Input variable
Measured value
-
Version A
distance between lower edge of the flange and
product surface
-
version B, C and D
distance between lower edge of the transducer and
product surface
5)
Depending on size and process fitting material.
VEGASON
64 • Profibus PA
49
10 Supplement
28787
-
EN
-081127