Vegapuls 62 - standpipe version with flange – VEGA VEGAPULS 62 (≥ 2.0.0 - ≤ 3.8) standpipe ver. Foundation Fieldbus User Manual
Page 59
VEGAPULS 62 - Standpipe version with flange
ø 39,5 mm
(1.56")
ø 21,3 mm
(0.84")
203 mm (7.99")
33 mm (1.30")
4xø0.75"
4xø0.75"
8xø0.75"
8xø0.87"
8xø0.88"
4.75"
4.92"
6.30"
7.09"
9.45"
6.50"
4xø0.71"
4xø0.71"
8xø0.71"
8xø0.71"
4.33"
5.91"
0.71"
0.94"
0.94"
0.75"
0.87"
0.79"
0.95"
0.79"
7.87"
8.66"
11.22"
7.50"
7.50"
9.50"
6.00"
6.00"
9.00"
11.00"
1.00"
D
mm
b
k
d
DN 50 PN 40
165
20
125
4xø18
DN 80 PN 40
200
24
160
8xø18
DN 100 PN 16
220
20
180
8xø18
DN 150 PN 16
285
22
240
8xø22
2" 150 lb
152,4
19,1
120,7
4xø19,1
3" 150 lb
190,5
23,9
152,4
4xø19,1
4" 150 lb
228,6
23,9
190,5
8xø19,1
6" 150 lb
279,4
25,4
241,3
8xø22,4
DN 40 PN 40
150
18
110
4xø18
D
inch
b
k
d
DN 50 PN 40
DN 40PN 40
DN 80 PN 40
DN 100 PN 16
DN 150 PN 16
2" 150 lb
3" 150 lb
4" 150 lb
6" 150 lb
L
b
D
k
d
Fig. 29: VEGAPULS 62 - Standpipe version with flange
14)
14)
The plant operator must provide a suitable support for the standpipe de-
pending on the length and the process conditions.
VEGAPULS
62 standpipe version • Foundation Fieldbus
59
10 Supplement
28740
-EN
-090305
- VEGABAR 25 (24 pages)
- VEGAFLEX 55K (32 pages)
- VEGABAR 17 (36 pages)
- D80 Hydrostatic pressure transmitters (40 pages)
- VEGAMET 513 (52 pages)
- D81 Hydrostatic pressure transmitter (44 pages)
- VEGASTAB 690 (12 pages)
- VEGASWING 83 fail safe and signal conditioning instrument VEGATOR 526 Ex (28 pages)
- VEGACONNECT 2 (4 pages)
- D81 METEC Hydrostatic pressure transmitter (44 pages)
- VEGAPULS 45 4 … 20 mA; HART compact sensor (72 pages)
- VEGAMET 515 (68 pages)
- VEGAFLEX 52K (32 pages)
- Capacitive electrodes EK Profibus PA (56 pages)
- VEGATOR 631 S1 (4 pages)
- VEGAPULS 63 (≥ 2.0.0 - ≤ 3.8) 4 … 20 mA_HART - two-wire (68 pages)
- Capacitive electrodes EK 4 … 20 mA - Compact (40 pages)
- VEGABAR 65 4 … 20 mA_HART (76 pages)
- VEGABAR 64 Profibus PA (80 pages)
- VEGABAR 44 4 … 20 mA (28 pages)
- VEGADIS 50 Ex (8 pages)
- VEGAPULS 51V…54V (96 pages)
- VEGAFLEX 54P (Profibus PA) (48 pages)
- VEGASEL 643 (16 pages)
- VEGAPULS 56K (68 pages)
- VEGAFLEX 54K (36 pages)
- VEGABAR 41 HART (44 pages)
- VEGATOR 537 Ex (16 pages)
- VEGACAP 82-98 (36 pages)
- VEGADIS 371 Ex (20 pages)
- Capacitive electrodes EL Profibus PA (56 pages)
- VEGAFLEX 52V (36 pages)
- VEGAFLEX 51K (32 pages)
- VEGALOG 571 EP (Ex) (32 pages)
- D84 Hydrostatic pressure transmitter (44 pages)
- VEGABAR 64 Foundation Fieldbus (80 pages)
- VEGABAR 61 4 … 20 mA_HART (80 pages)
- VEGASCAN 850 (92 pages)
- VEGASON 54P…56P Profibus PA (68 pages)
- D77 Hydrostatic pressure transmitters (24 pages)
- VEGATRENN 546 Safety barrier type 146 (8 pages)
- VEGASON 71 - 1 … 75 - 1 (52 pages)
- VEGABAR 40 HART (40 pages)
- Capacitive electrodes EL … (44 pages)
- VEGABAR 24 (28 pages)