VEGA VEGAPULS 62 (≥ 2.0.0 - ≤ 3.8) standpipe ver. Foundation Fieldbus User Manual
Page 48
Process conditions
Process temperature (measured on the process fitting), depending on seal and antenna system
-
FKM (Viton)
-40 … +200 °C (-40 … +392 °F)
-
FFKM (Kalrez 6375)
-20 … +200 °C (-4 … +392 °F)
-
FFKM (Kalrez 2035, 6230)
-15 … +200 °C (+5 … +392 °F)
FKM (Viton) with impedance cone PP
-40 … +80 °C (-40 … +176 °F)
FFKM (Kalrez 6375) with impedance cone
PP
-15 … +80 °C (+5 … +176 °F)
For the vessel pressure, you also have to note the specifications on the type label. Always the
lowest value is applicable.
Vessel pressure
-100 … 4000 kPa/-1 … 40 bar (-14.5 … 580 psig)
Vessel pressure relating to the flange nom-
inal stage
see supplementary instructions manual "Flanges
according to DIN-EN-ASME-JIS"
Vibration resistance
mechanical vibrations with 1 g and 5 … 100 Hz
10)
Electromechanical data - version IP 66/IP 67 and IP 66/IP 68; 0.2 bar
Cable entry/plug
11)
-
Single chamber housing
l
1 x cable gland M20 x 1.5 (cable: ø 5 … 9 mm),
1 x blind stopper M20 x 1.5
or:
l
1 x closing cap M20 x 1.5; 1 x blind stopper
M
20 x 1.5
or:
l
1 x closing cap ½ NPT, 1 x blind plug ½ NPT
or:
l
1 x plug (depending on the version), 1 x blind
stopper M20 x 1.5
-
Double chamber housing
l
1 x cable entry M20 x 1.5 (cable: ø 5 … 9 mm),
1 x blind stopper M20 x 1.5; 1 x blind stopper
M
16 x 1.5 or optionally available with 1 x plug
M
12 x 1 for VEGADIS 61
or:
l
1 x closing cap ½ NPT, 1 x blind stopper
½ NPT
, 1 x blind stopper M16 x 1.5 or
optionally 1 x plug M12 x 1 for VEGADIS 61
or:
l
1 x plug (depending on the version), 1 x blind
stopper M20 x 1.5; 1 x blind stopper M16 x 1.5
or optionally available with 1 x plug M12 x 1 for
VEGADIS
61
10)
Tested according to the regulations of German Lloyd, GL directive 2.
11)
Depending on the version M12 x 1, according to DIN 43650, Harting, 7/
8" FF.
48
VEGAPULS
62 standpipe version • Foundation Fieldbus
10 Supplement
28740
-EN
-090305