beautypg.com

VEGA VEGASON 62 4 … 20 mA_HART - two-wire User Manual

Page 15

background image

15

4 Mounting

VEGASON 62 • 4 … 20 mA/HART - two-wire

28776-EN-130417

Fig. 12: Agitators

Do not mount the instruments in or above the filling stream. Make sure

that you detect the product surface, not the inflowing product.

Fig. 13: Inflowing liquid

Through the action of filling, stirring and other processes in the vessel,

dense foams which considerably damp the emitted signals may form

on the product surface.
If foams are causing measurement errors, the sensor should be used

in a standpipe or, alternatively, the more suitable guided radar sen-

sors (TDR) should be used.
Guided wave radar is unaffected by foam generation and is particu-

larly suitable for such applications.

If there are strong air currents in the vessel, e.g. due to strong winds

in outdoor installations or air turbulence, e.g. by cyclone extraction

you should mount VEGASON 62 in a standpipe or use a different

measuring principle, e.g. radar or guided radar (TDR).

Inflowing medium

Foam

Air turbulences