beautypg.com

VEGA VEGASON 63 4 … 20 mA_HART - two-wire User Manual

Page 45

background image

45

10 Supplement

VEGASON 63 • 4 … 20 mA/HART - two-wire

28777-EN-130417

Ʋ Inspection window

Polyester foil

Voltage supply
Operating voltage

14 … 36 V DC

Operating voltage with illuminated dis-

play and adjustment module

10)

20 … 36 V DC

Permissible residual ripple

Ʋ < 100 Hz

U

ss

< 1 V

Ʋ 100 Hz … 10 kHz

U

ss

< 10 mV

Load

see diagram

1000

750

500

250

14

18

16

20

22

24

26

28

30

32

34

36

V

4

1

2

3

Fig. 29: Voltage diagram
1 HART load

2 meaningless

3 Voltage limit

4 Operating voltage

Electrical protective measures
Protection, depending on housing version

Ʋ Plastic housing

IP 66/IP 67

Ʋ Aluminium housing, stainless steel

housing - investment casting, stain-

less steel housing - electro-polished

IP 66/IP 68 (0.2 bar)

11)

Overvoltage category

III

Protection class

II

Functional safety (SIL)
Functional safety is already activated on instruments with SIL qualification ex factory. On instru-

ments without SIL qualification ex factory, the functional safety must be activated by the user via

the display and adjustment module or via PACTware for applications according to SIL.

Functional safety according to IEC 61508-4

Ʋ Single channel architecture (1oo1D) up to SIL2

10)

For instruments with national approvals such as e.g. according to CSA, only available at a later date.

11)

A suitable cable is the prerequisite for maintaining the protection rating.