VEGA VEGASON 63 4 … 20 mA_HART - two-wire User Manual
Page 44
44
10 Supplement
VEGASON 63 • 4 … 20 mA/HART - two-wire
28777-EN-130417
Process conditions
Process pressure
Ʋ with compression flange
-20 … 100 kPa/-0.2 … 1 bar (-2.9 … 14.5 psi)
Ʋ with mounting strap
0 kPa, since no seal possibility
Process temperature (transducer tem-
perature)
-40 … +80 °C (-40 … +176 °F)
Vibration resistance
mechanical vibrations with 4 g and 5 … 100 Hz
8)
Electromechanical data - version IP 66/IP 67 and IP 66/IP 68; 0.2 bar
Cable entry/plug
9)
Ʋ Single chamber housing
– 1 x cable gland M20 x 1.5 (cable: ø 5 … 9 mm), 1 x
blind plug M20 x 1.5
or:
– 1 x closing cap M20 x 1.5; 1 x blind plug M20 x 1.5
or:
– 1 x closing cap ½ NPT, 1 x blind plug ½ NPT
or:
– 1␣x plug (depending on the version), 1␣x blind stopper
M20␣x␣1.5
Ʋ Double chamber housing
– 1 x cable entry M20 x 1.5 (cable: ø 5 … 9 mm), 1 x
blind plug M20 x 1.5; 1 x blind plug M16 x 1.5 or
optionally available with 1 x plug M12 x 1 for external
display and adjustment unit
or:
– 1 x closing cap ½ NPT, 1 x blind plug ½ NPT, 1 x blind
plug M16 x 1.5 or optionally 1 x plug M12 x 1 for exter-
nal display and adjustment unit
or:
– 1 x plug (depending on the version), 1 x blind plug
M20 x 1.5; 1 x blind plug M16 x 1.5 or optionally avail-
able with 1 x plug M12 x 1 for external display and
adjustment unit
Spring-loaded terminals for wire cross-
section
< 2.5 mm² (AWG 14)
Display and adjustment module
Voltage supply and data transmission
through the sensor
Indication
LC display in dot matrix
Adjustment elements
4 keys
Protection rating
Ʋ unassembled
IP 20
Ʋ mounted into the sensor without cover IP 40
Material
Ʋ Housing
ABS
8)
Tested according to the guidelines of German Lloyd, GL directive 2.
9)
Depending on the version M12 x 1, according to DIN 43650, Harting, 7/8" FF.