VEGA VEGACAL 66 Foundation Fieldbus User Manual
Page 39
39
10 Supplement
VEGACAL 66 • Foundation Fieldbus
30038-EN-130917
1
2
-50˚C
(-58˚F)
50˚C
(122˚F)
40˚C
(104˚F)
-40˚C
(-40˚F)
80˚C
(176˚F)
0˚C
(32˚F)
100˚C
(212˚F)
150˚C
(302˚F)
Fig. 24: Ambient temperature - Process temperature
1 Process temperature
2 Ambient temperature
Dielectric constant
≥ 1.5
Electromechanical data - version IP 66/IP 67 and IP 66/IP 68; 0.2 bar
Cable entry/plug
2)
Ʋ Single chamber housing
– 1 x cable gland M20 x 1.5 (cable: ø 5 … 9 mm), 1 x
blind plug M20 x 1.5
or:
– 1 x closing cap M20 x 1.5; 1 x blind plug M20 x 1.5
or:
– 1 x closing cap ½ NPT, 1 x blind plug ½ NPT
or:
– 1␣x plug (depending on the version), 1␣x blind stopper
M20␣x␣1.5
Ʋ Double chamber housing
– 1 x cable entry M20 x 1.5 (cable: ø 5 … 9 mm), 1 x
blind plug M20 x 1.5; 1 x blind plug M16 x 1.5 or
optionally available with 1 x plug M12 x 1 for external
display and adjustment unit
or:
– 1 x closing cap ½ NPT, 1 x blind plug ½ NPT, 1 x blind
plug M16 x 1.5 or optionally 1 x plug M12 x 1 for exter-
nal display and adjustment unit
or:
– 1 x plug (depending on the version), 1 x blind plug
M20 x 1.5; 1 x blind plug M16 x 1.5 or optionally avail-
able with 1 x plug M12 x 1 for external display and
adjustment unit
Spring-loaded terminals for wire cross-
section
< 2.5 mm² (AWG 14)
Electromechanical data - version IP 66/IP 68 (1 bar)
Cable entry
Ʋ Single chamber housing
1 x IP 68 cable gland M20 x 1.5; 1 x blind plug M20 x 1.5
2)
Depending on the version M12 x 1, according to DIN 43650, Harting, 7/8" FF.