background image

Fig. 17: Purging air connection with parabolic antenna

I

n practice it was shown that a pressure of approx. 0.2 … 1 bar is

enough to provide a sufficient air flow (see diaphragm in chapter
"

Technical data").

L

arge material heaps are detected with several sensors, which can be

mounted on e.g. traverse cranes. For this type of application, it is best
to orient the sensor toward the solid surface. A mutual infuence of the
sensors is not possible.

Fig. 18: Radar sensors on traverse crane

Information:
K

eep in mind that for these applications, the sensors are designed for

relatively slow level changes. When using VEGAPULS 68 on a
movable bracket, the max. measuring rate must be observed (see
chapter "Technical data").

Material heaps

VEGAPULS

68 • 4 … 20

mA/HART four-wire

25

4 M

ounting

29262

-EN