C

heck, if the O-ring seal is available on the connection piece and if

it is not damaged.

Note:
A

damaged O-ring seal must be replaced: FKM (Viton) article no.

2.28248, FFKM (K

alrez 6375) article no. 2.27351

8

R

emount the parabolic antenna (4)

9

T

ighten compression nut (1) with SW 41, torque max. 50 Nm

10 T

ighten locknut (2) with SW 36, torque max. 40 Nm.

Note:
T

ake note for VEGAPULS 68 with rinsing air connection that the holes

in the antenna and in the process fitting correspond. This ensures a
sufficient air flow (the air is led through the holes to the feed system. A
rinsing of the parabolic antenna in total is not intended).

1

2

3

4

Fig. 6: Dismounting, parabolic antenna

1

Compression nut

2

Locknut

3

Connection piece

4

Parabolic antenna

4.4 Mounting instructions

T

he illustrations with the following mounting instructions show a

VEGAPULS

68

with horn antenna. The mounting instructions apply

analogously also to the version with parabolic antenna.

M

ount the sensor at least 200 mm (7.874 in) away from the vessel

wall.

Horn and parabolic an-
tenna

Mounting position

16

VEGAPULS

68 • 4 … 20

mA/HART four-wire

4 M

ounting

29262

-EN

-090305