beautypg.com

VEGA VEGAPULS 68 (≥ 2.0.0 - ≤ 3.8) 4 … 20 mA_HART four-wire User Manual

Page 22

background image

d

h

max.

d

1½"

50 mm/2"

80 mm/3"

100 mm/4"

150 mm/6"

200 mm

250 mm

300 mm

500 mm

800 mm

h

max.

Fig. 12: Deviating socket dimensions

Tip:
VEGAPULS

68

is optionally also available with antenna extension.

H

ence the antenna length can be selected such that the antenna end

protrudes 10 mm (0.4 in) out of the socket.

T

he silo walls of multiple chamber silos are often made of profile walls,

such as e.g. profile sheeting, to ensure the required stability. If the
radar sensor is mounted very close to a heavily structured vessel wall,
considerable false reflections can be generated. Hence the sensor
should be mounted at a large distance from the separating wall. The
optimal mounting position is on the outer wall of the silo with the sensor
directed towards the emptying aperture in the silo center.

Mounting in multiple
channel silo

22

VEGAPULS

68 • 4 … 20

mA/HART four-wire

4 M

ounting

29262

-EN

-090305