6 Setup with the integrated display and adjustment unit
VEGASCAN 693 • 15-channel HART signal conditioning instrument
29252-EN-130701
→
Enter the requested values via the appropriate keys and save
your settings with [OK].
For instruments with integrated Ethernet interface, the automatic
addressing via DHCP is preset, i.e. the IP address must be assigned
by a DHCP server. Generally the instrument is contacted via the Host
name. By default, the host name consists of the serial number plus
"VEGA-" in front. As an alternative, it is also possible to enter a static
IP addr. with Subnet mask and optional Gateway addr.
Note:
Keep in mind that your modification will be only effective after a restart
of VEGASCAN 693. You can find further information of these network
parameters in the supplementary instructions "RS232/Ethernet con-
nection" and in the Online help of the respective DTM.
Carry out your settings via the appropriate keys and save with [OK].
→
Carry out your settings via the appropriate keys and save with
[OK]. Disconnect briefly the operating voltage so that the modi-
fied settings become effective.
Date and time can be entered in this menu item for instruments with
integrated RS232/Ethernet interface. These time settings are buffered
in case of power failure for approx. 3 days.
→
Enter the values via the appropriate keys and save your settings
with [OK].
For instruments with integrated RS232 interface, you determine here
which mode this serial interface should operate in. The following op-
tions are available:
•
VVO protocol: Direct standard connection between signal condi-
tioning instrument and PC for parameter adjustment and enquiry
(e.g. with PACTware and DTM)
•
PPP: Dial-up connection between signal conditioning instrument
and modem for independent transmission of e-mails (dial-out con-
nection) or enquiry via web browser (dial-in connection)
•
ASCII protocol: Direct standard connection between signal con-
ditioning instrument and PC for enquiry with terminal programs,
e.g. Hyperterminal
Device settings - Host
Name/IP addr.
Device settings - Time/
Date
Device settings - Commu-
nication protocol