VEGASON 51K … 53K
19
Technical data
Ambient conditions
Max. vessel pressure (gauge pressure)
- VEGASON 51 and 52
3 bar
- VEGASON 53
1 bar
Ambient temperature
- sensor (electronics)
-20°C … +60°C
- process (transducer)
-40°C … +80°C (StEx: -20°C … +75°C)
- storage and transport temperature
-40°C … +80°C
Protection
- sensor
IP 67
- transducer, process
IP 68
Protection class
- two-wire sensor
II
- four-wire sensor
I
Overvoltage category
III
Self-heating
at 40°C ambient temperature
- to sensor
45°C
- to transducer, process
55°C
Ex-technical data
Classification
ia intrinsically safe (in conjunction with a safety
barrier or separator)
Temperature class (permissible ambient
temperature on the transducer when used
in Ex-areas)
- T6
42°C
- T5
58°C
- T4
60°C
- T3
60°C
Ex-approved in category or zone
- ATEX
Zone 1 (II 2 G)
- IEC, CENELEC, PTB
Zone 1 (II 2 G)
Classification mark
EEx ia IIC T6
Process connections
VEGASON 51
G 1
1
/
2
A, 1
1
/
2
" NPT
VEGASON 52
G 2 A, 2" NPT
VEGASON 53
DN 100 compression flange
Connection lines
Two-wire sensors
supply and voltage via one two-wire line,
load dependent on the supply voltage
Four-wire sensor
supply and signal separately, load of the
4 … 20 mA-signal line max. 500
Ω
Cross-section area of conductor
generally 2,5 mm
2
Earth connection
max. 4 mm
2
Cable entry, Pg
2 x M20 x 1,5 (cable diameter 5 … 9 mm)