beautypg.com

VEGA VEGASON 51K…53K User Manual

Page 14

background image

14

VEGASON 51K … 53K

-

+

4 ... 20 mA

VEGADIS

371 Ex

2

2

2

4

Measuring system with VEGASON 51K … 53K on the indicating instrument
VEGADIS 371 Ex with current and relay output

• Two-wire technology (loop powered), intrinsically safe ia-supply via the signal line from the

indicating instrument VEGADIS 371 Ex for operation of the sensor in Ex-zone 1

• Optional external indicating instrument with analogue and digital indication (can be mounted

up to 25 m away from the sensor)

• Adjustment with PC, HART

®

-handheld or adjustment module MINICOM (can be plugged in

the sensor or in the external indicating instrument VEGADIS 50)

Types and versions

(passive)

VEGADIS 50

0/4 … 20 mA

Relay

(see "3.2 Approvals“)

1 )

Ex-area

Not Ex-area

HART

®

-handheld

VEGA-
CONNECT 2

1)

If the resistors of the processing systems
connected to the 4 … 20 mA-signal output are less
than 200

, a resistor of 250

to 350

must be

connected to the connection line during adjust-
ment.
The digital adjustment signal would be extremely
damped or short-circuited via too small input
resistors of the connected processing system
which means that the digital communication with
the PC could no longer be ensured.