4 approvals and certificates – VEGA D96_D97 Profibus PA User Manual
Page 9

Pressure transmitter D96/D97 (Profibus PA)
9
Product description
Operating conditions
Ambient conditions
Ambient temperature
-40°C … +85°C
- with indicating module
-20°C … +70°C
Storage and transport temperature
-40°C … +85°C
Pressure transmitter D96
Product temperature
with Viton seal
tube version
-20°C … +85°C
FEP suspension hose
-20°C … +85°C
PE cable
-20°C … +60°C
with EPDM seal
tube version
-40°C … +85°C
FEP suspension hose
-40°C … +85°C
PE cable
-40°C … +60°C
with Hilfuor seal
tube version
-10°C … +85°C
FEP suspension hose
-10°C … +85°C
PE cable
-10°C … +60°C
with Kalrez seal
tube version
0°C … +85°C
FEP suspension hose
0°C … +85°C
PE cable
0°C … +60°C
Pressure transmitter D97
Product temperature
tube version
-40°C … +85°C
FEP suspension hose
-40°C … +85°C
PE cable
-40°C … +60°C
1.4 Approvals and certificates
Approvals
- Ex Zone 2
- CENELEC EEx ia IIC
- ATEX II 1G EEx ia IIC
If the use of approved instruments is required for certain applications, the appropriate
official documents (test reports, test certificates and conformity certificates) must be ob-
served. These are supplied with the respective instrument.
CE conformity
D96 and D97 pressure transmitters meet the requirements of EMC (89/336/EWG) and NSR
(73/23/EWG). Conformity has been judged acc. to the following standards:
EMC
Emission
EN 50 081 - 1: 1992
Susceptibility
EN 50 082 - 2: 1995
NSR
EN 61 010 - 1: 1993
NAMUR regulations
Full compliance with the NAMUR regulations NE 21, May 1993.