beautypg.com

9 supplement, 1 technical data – VEGA VEGATOR 256C User Manual

Page 18

background image

9 Supplement

9.1 Technical data

General data
Series

Module unit for mounting on carrier rail 35x7.5

or 35x15 according to EN 50022

Dimensions

W = 37 mm (1.46 in), H = 68 mm (2.68 in), D =

66 mm (2.6 in)

Weight

approx. 170 g (6 oz)

Housing material

Noryl SE100, Lexan 920A

Voltage supply
Supply voltage
- Standard

200 … 250 V AC, 50/60 Hz

- optional

24 V, 42 V, 48 V, 100 … 130 V AC (+10 %,

-15 %)

Power consumption

1 VA

Sensor input
Quantity

1x level detection or 1x pump control (min./

max.)

Response resistor

1 … 200 kOhm adjustable

Measuring circuit

approx. 12 V eff., max. 1 mA

Switching hysteresis

approx. 20 %

Relay output
Quantity

1 (1x level detection)

Mode

Max. detection or overfill protection

Integration time

approx. 500 ms

Contact

Changeover contact (spdt)

Contact material

AgNi 0.15 hard gold-plated

Turn-on voltage

min. 10 mV DC, max. 250 V AC, 250 V DC

Switching current

min. 10 µA DC, max. 5 A AC, 1 A DC

Breaking capacity

max. 750 VA, max. 54 W

Adjustment elements
Control lamp

to the indication of the relay switching status

Potentiometer

to the adaptation of the product conductivity

18

VEGATOR 256C - Signal conditioning instrument

Supplement

23409

-EN
-070316