beautypg.com

VEGA VEGAWELL 72 4 … 20 mA User Manual

Page 33

background image

-

F

T

: T

emperature coefficient (influ-

ence of medium or ambient tem-
perature)

-

F

K

l

: D

eviation

Ambient conditions

A

mbient temperature

-

C

onnection cable PE

-40 … +60 °C (-40 … +140 °F)

-

C

onnection cable PUR, FEP

-40 … +80 °C (-40 … +176 °F)

S

torage and transport temperature

-40 … +80 °C (-40 … +176 °F)

Process conditions

M

ax. process pressure, transmitter

6)

-

M

easuring range 0.1 bar (1.45 psig)

15

bar (218 psig)

-

M

easuring range 0.2 bar (2.9 psig)

20

bar (290 psig)

-

M

easuring range ≤ 0.4 bar (5.8 psig)

25

bar (363 psig)

P

ressure stage, process fitting

-

U

nassembled threaded fitting

316L: PN 3, PVDF:

unpressurized

-

T

hread on the housing

PN

3

P

roduct temperature, depending on the version

Suspension cable

Measuring cell seal

Product temperature

PE

FKM

-20 … +60 °C (-4 … +140 °F)

PUR

FKM

-20 … +80 °C (-4 … +176 °F)

PUR

FFKM

-20 … +80 °C (-4 … +176 °F)

FEP

FFKM

-10 … +80 °C (+14 … +176 °F)

Connection tube

Measuring cell seal

Product temperature

316L

FFKM

-20 … +80 °C (-4 … +176 °F)

Transmitter protection

Measuring cell seal

Product temperature

PVDF

FFKM

-10 … +60 °C (+14 … +140 °F)

PE

FKM (V

iton)

-20 … +60 °C (-4 … +140 °F)

PE

FFKM

-10 … +60 °C (+14 … +140 °F)

V

ibration resistance

mechanical vibrations with 4 g and
5 … 100 H

z

7)

6)

L

imited by the overpressure resistance of the measuring cell.

7)

T

ested according to the regulations of German Lloyd, GL directive 2.

VEGAWELL

72 • 4 … 20

mA

33

9 S

upplement

27501

-

EN

-080806