P

ulse duration

<

2

ns

-

A

verage power

<

5 µW

-

A

verage power with 1 m distance

<

200

nW/cm

2

M

ax. emitted HF power of the antenna system - Version with increased sensitivity

-

P

ulse peak power

<

10

mW

-

P

ulse duration

<

2

ns

-

A

verage power

<

25 µW

-

A

verage power with 1 m distance

<

1 µW/

cm

2

Measuring accuracy

R

esolution, general

max. 1 mm (0.039 in)

D

eviation

7)

see diagrams

0,5 m (1.6 ft)

20 m (65.62 ft)

10 mm (0.394 in)

3 mm (0.116 in)

- 3 mm (- 0.116 in)

- 10 mm (- 0.394 in)

0

Fig. 25: Deviation VEGAPULS 63

1,0 m (3.280 ft)

20 m (65.62 ft)

30 mm (1.180 in)

15 mm (0.590 in)

- 15 mm (- 0.590 in)

- 30 mm (- 1.180 in)

0

Fig. 26: Deviation VEGAPULS 63 with increased sensitivity in mm, measuring range in m

Influence of the ambient temperature to the sensor electronics

8

)

7)

I

ncl. non-linearity, hysteresis and non-repeatability.

8)

R

elating to the nominal measuring range, in the temperature range

-40 … +80 °C .