VEGA D81 METEC Hydrostatic pressure transmitter User Manual
Page 11
Pressure transmitter D81 METEC
®
11
Product description
Supply and signal circuit (analogue transmission, 4 … 20 mA),
additional data for electronics version L
Supply voltage for pressure transmitters
in conjunction with VEGADIS 12
- without display
12 … 36 V DC
- with display
17 … 36 V DC
Max. input current
150 mA
Current signal range
3.5 … 22 mA
Max. permissible load
see load diagram:
Load diagram with display
300
500
700
18
24
30
36
100
Load in
Ω
Supply voltage
in V
Supply and signal circuit on VEGA signal conditioning instruments (digital signal
transmission VBUS), additional data for electronics version B
Supply voltage
25 … 36 V DC, from VEGAMET (VBUS) or
from VEGALOG 571 with EV input card
Data transmission
digital (VBUS)
Connection cable
2-wire screened
Cable length
max. 1000 m
Integrated overvoltage protection (option)
Nominal response DC voltage
- protective diode
40 V
- gas separator
650 V
Nominal leakage current
- gas separator
20 kA
Connection cables
Cable entry
- housing
2 x M20x1.5 (for cable ø 5…9mm or 9…12mm)
- external connection housing
2 x M20x1.5 (for cable ø 5…9mm or 9…12mm)
Screw terminals
- sensor
for wire cross-sections up to 2.5 mm
2
- external connection housing
for wire cross-sections up to 2.5 mm
2