Electric lock connection, Door lock controlled with internal power, Door lock controlled with dry contact – V-Tech DT596F_ID Manual User Manual
Page 7: Jumper position in connect two locks

Electric Lock Connection
Door Lock Controlled with Internal Power
•••••Note:
1.• Electronic•lock•of•Power-on-to-unlock•type•should•be•used.
2.• The•door•lock•is•limited•to•12V,•and•holding•current•must•be•less•than•250mA.
3.• The•door•lock•control•is•not•timed•from•Exit•Button(EB).
4.• The•Unlock Mode•Parameter•of•Monitor•must•be•set•to•0•(by•default).
Door Lock Controlled with Dry Contact
•••••Note:
1.• The•external•power•supply•must•be•used•according•to•the•lock.
2.• The•inside•relay•contact•is•restricted•to•AC•or•DC•24V/1A.
3.• The•jumper•must•be•taken•off•before•connecting.
4.• Setup•the•Unlock Mode•of•Monitor•for•different•lock•types.
•• Power-on-to-unlock•type:Unlock•Mode=0•(by•default)
•• Power-off-to-unlock•type:Unlock•Mode=1
EB
*
LOCK
BUS
PL
S1+
S2+
S-
LOCK
2
nd
1
ST
2
nd
EB
*
1
ST
Jumper position in
Connect two locks
2-3
1 2 3
EB
*
LOCK
BUS
PL
S1
+
S2
+
S-
Jumper position in
Connect one lock
2-3
1 2 3
-5-