beautypg.com

Error messages, Specifications – Ohaus DS Series Electronic Digital Bench Scales User Manual

Page 20

background image

12

Error Messages

Error Messages

Error Messages

Error Messages

Error Messages

Overload:

The load on the platform exceeds the
capacity of the scale.

Underload:

Platform has been removed.

Low Battery: NiCad battery pack must be charged.

Models

DS4

DS10

DS10L

DS20L

DS44L

Capacity (lb)

44

110

110

220

440

Readability (lb)

0.02

0.05

0.05

0.1

0.2

Capacity (kg)

20

50

50

100

200

Readability (kg)

0.01

0.02

0.02

0.05

0.1

All Models

Linearity

3 divisions

Auto zero tracking

capture range

0.5 divisions

Tare range

To Capacity by Subtraction

Over range capacity

Capacity + 9 divisions

Stabilization time

3 seconds

Shift accuracy

± 1 division

Operating temperature

32° to 104°F/0° to 40° C

Weighing system

4 corner strain gauge load cells

Display (in/cm)

LCD (0.8/2 high)

Power requirements

Built in NiCad rechargeable battery pack or

AC Adapter/Charger: 120, 220, 240 V ac

Platform size (in/cm)

12.2 x 1.4 x 10.8/

20.5 x 2.7 x 15.7/

(W x H x D)

31 x 3.6 x 27.4

52.1 x 6.9 x 40

Indicator size (in/cm)

10.2 x 2.4 x 5.5/

(W x H x D)

25.9 x 6.1 x 5.5

Net weight (lb/kg)

8.8/4

33/15

SPECIFICATIONS

SPECIFICATIONS

SPECIFICATIONS

SPECIFICATIONS

SPECIFICATIONS