Driver installation – Manhattan 176767 SATA 1.5 Gb_s RAID Controller PCI Card - Manual User Manual
Page 6

Deleting RAID Sets
1. As the BIOS boots, press CTRL+S or F4 to enter the raid bios utility.
2. Select "Delete RAID set." Press Enter.
3. Answer "Y" to remove the RAID set. If the RAID set being deleted is
a Striped set, then all of the data will be lost. If the set being deleted
is a Mirrored set, then the data will remain intact and accessible on
both drives.
Rebuilding Mirrored Sets
1. After replacing the failed hard drives, boot the BIOS, then press CTRL+S
or F4 to enter the RAID BIOS utility.
2. Select "Rebuilding Mirrored Set." Press Enter.
3. Select "Online Rebuild” or “Offline Rebuild."
4. Answer "Y" to rebuild the Mirrored set of the hard drive.
Resolving Conflict
When a RAID set is created, the metadata written to the disk includes
drive connection information (primary and secondary). If, after a disk
failure, the replacement disk was previously part of a RAID set (or used
in another system), it may have conflicting metadata, specifically in
reference to the drive connection information. If so, this will prohibit the
RAID set from being either created or rebuilt. For the RAID set to function
properly, this old metadata must be first overwritten with the new metadata.
To resolve this, select "Resolve Conflicts," and the correct metadata,
including the correct drive connection information, will be written to the
replacement disk.
DRIveR InSTAllATIon
For New Windows 2000 Systems
NOTE: Before installation, copy all the files under directory E:\SATA
Raid_2Port\Sil3x12\Win98_me_2000_xp_nt4.0\driver\*.* to a blank
disk. Once the SATA 150 RAID Controller PCI Card and attached drives
are configured, follow Microsoft procedures to install Windows.