beautypg.com

3 redundancy status in ipedit, Redundancy status in ipedit, Edundancy – EVS IPDirector Version 5.8 - July 2010 Part 8 User's Manual User Manual

Page 11: Tatus in

background image

Issue 5.8.A

IP Director – Version 5.8 – User’s Manual – Part 8

EVS Broadcast Equipment – July 2010

1.2.3 R

EDUNDANCY

S

TATUS IN

IPE

DIT

You can check that both Master and Slave EVS servers are correctly connected in
the Status bar of IPEdit.

The following connection status information related to the Master/Slave

redundancy can be displayed:

Displayed information On M/S

Meaning

Connected to master

On
Slave
server

The EVS server is available and the SDTI
connection is established between the Master
and the Slave servers.

Connected to slave

On

Master
server

The EVS server is available and the SDTI

connection is established between the Master
and the Slave servers.

Error: not connected to

master

On
Slave
server

The Master server is not available on the
routing.

Error: not connected to

slave

On
Master
server

The Slave server is not available on the
routing.

Error: No SDTI
between master and

slave

On
Slave
server

No SDTI connection is established between
the Master EVS server and the Slave EVS
server.

Error: No SDTI

between slave and

master

On

Master
server

No SDTI connection is established between

the Master and Slave EVS servers.

10