beautypg.com

Dell PowerEdge R810 User Manual

Page 14

background image

12

Getting Started With Your System

Environmental

NOTE:

For additional information about environmental measurements for specific

system configurations, see

www.dell.com/environmental_datasheets.

Temperature

Operating

10° to 35°C (50° to 95°F) with a maximum
temperature gradation of 10°C per hour

NOTE:

For altitudes above 2950 feet,

the maximum operating temperature is
derated 1ºF/550 ft.

Storage

–40° to 65°C (–40° to 149°F) with
a maximum temperature gradation of
20°C per hour

Relative humidity

Operating

20% to 80% (noncondensing) with
a maximum humidity gradation of
10% per hour

Storage

5% to 95% (noncondensing)

Maximum vibration

Operating

0.26 G at 5–350 Hz for 15 min

Storage

0.5 G at 3–200 Hz for 15 min

Maximum shock

Operating

One shock pulse in the positive z axis
(one pulse on each side of the system) of
31 G for 2.6 ms in the operational orientation

Storage

Six consecutively executed shock pulses
in the positive and negative x, y, and z axes
(one pulse on each side of the system)
of 71 G for up to 2 ms