Bosch GAS 35 L SFC+ Professional User Manual
Page 21
English | 21
Bosch Power Tools
1 609 92A 0E0 | (25.7.13)
conforming with the valid regulations for the disposal of such
waste.
For maintenance on behalf of the user, the vacuum cleaner
must be disassembled, cleaned and maintained as far as fea-
sible, without causing a risk for the maintenance personnel or
other persons. Prior to disassembly, the vacuum cleaner
should be cleaned in order to prevent any risks. The room/en-
closure in which the vacuum cleaner is disassembled should
be well ventilated. Wear personal protective equipment dur-
ing maintenance. After the maintenance, the maintenance ar-
ea should be cleaned.
Removing/Replacing the Flat-fold Filter (see figures J1 –
J2)
Replace a damaged flat-fold filter 24 immediately.
– Pull the locking latch 14 and open the filter cover 34.
– Grasp the flat-fold filter 24 by the fins, pull up and remove.
– When taking out the flat-fold filter 24, remove any accumu-
lating dust and debris from the closing edge of the filter
cover 34 using a moist cloth.
– Insert the new flat-fold filter 24; observe proper and tight
seating.
– Shut the filter cover 34 again (must be heard to engage).
Container
– Wipe out the container 1 from time to time with a commercial-
ly available, non-scouring cleaning agent and allow to dry.
Level Sensors (see figure K)
Clean the level sensors 35 occasionally.
– Unlock the latches 9 and remove the vacuum lid 8.
– Clean the level sensors 35 with a soft cloth.
– Reattach the vacuum lid 8 again and lock the latches 9.
Storage and Transport (see figure L)
– Wind the mains cable around the cable holder 13.
– Insert the accessories into the holders provided: Vacuum
tubes 29 in holders 15, crevice nozzle 25 in holder 16,
floor nozzle 28 in holder 17.
– Undue the elastic tie-downs of the vacuum-hose holders 4
and place the vacuum hose 21 around the vacuum cleaner
lid into the holders 4.
Reattach the elastic tie-downs.
– Mount the L-Boxx onto the retainers 7.
– To prevent back injuries, remove a full disposal bag or dust
bag, or drain vacuumed-up fluids before transporting the
vacuum cleaner.
Carry the vacuum cleaner only by the carrying handle 6.
– Store the vacuum cleaner in a dry room and secure it
against unauthorised use.
– To lock the castors 12, actuate the castor brakes 11 by
pushing down.
Correction of Malfunctions
Problem
Corrective Measure
The vacuum turbine does not start.
– Check mains cable, mains plug, fuse, socket outlet and filling-
level sensors 35.
Mode selector switch 5 set to “Start/Stop automatic”.
– Set mode selector switch 5 to the “vacuum” symbol and
switch the power tool connected to the socket outlet 3 on.
Vacuum turbine switches off.
– Empty container 1.
Vacuum turbine does not restart after emptying the container. – Switch vacuum cleaner off and wait 5 seconds; switch on
again after 5 seconds.
– Clean level indicators 35 as well as the space between the lev-
el indicators 35 with a brush.
Vacuuming power decreases.
– Remove clogs from vacuum nozzle, vacuum tubes 29, vacuum
hose 21 or flat-fold filter 24.
– Replace disposal bag 23 or dust bag.
– Engage filter cover 34 properly.
– Mount vacuum cleaner lid 8 properly and lock latches 9.
– Replace flat-fold filter 24.
Dust escapes during vacuuming
– Check proper installation of the flat-fold filter 24.
– Replace flat-fold filter 24.
The automatic shut-off (wet vacuuming) does not respond.
– Clean level indicators 35 as well as the space between the lev-
el indicators 35 with a brush.
The automatic shut-off does not function with non-conductive
liquids or foam/bubbles.
– Monitor the level continuously.
Filter cleaning inoperative.
– Push the SFC+ switch 18 toward the rear (position 1).
OBJ_BUCH-1702-002.book Page 21 Thursday, July 25, 2013 3:30 PM