Noise/vibration information, Declaration of conformity, Mounting and operation starting – Bosch GHP 8-15 XD Professional User Manual
Page 11
English | 11
Bosch Power Tools
F 016 L72 357 | (17.8.12)
Noise/Vibration Information
Measured sound values determined according to
2000/14/EC (1.60 m height, 1 m distance away).
Typically the A-weighted noise levels of the product are:
Sound pressure level 85.5 dB(A); sound power level
93 dB(A). Uncertainty K =3 dB.
Wear hearing protection!
Vibration total values a
h
(triax vector sum) and uncertainty K
determined according to EN 60335:
a
h
=4.91 m/s
2
, K=1.5 m/s
2
.
Declaration of Conformity
We declare under our sole responsibility that the product de-
scribed under “Technical data” is in conformity with the fol-
lowing standards or standardization documents: EN 60335
according to the provisions of the directives 2011/65/EU,
2004/108/EC, 2006/42/EC, 2000/14/EC.
2000/14/EC: Guaranteed sound power level 93 dB(A). Con-
formity assessment procedure according to Annex V.
Equipment category: 27
Technical file (2006/42/EC, 2000/14/EC) at:
Bosch Lawn and Garden Ltd., PT-LG/ENS,
Stowmarket, Suffolk IP14 1EY, England
Robert Bosch GmbH, Power Tools Division
D-70745 Leinfelden-Echterdingen
29.06.2012
Mounting and Operation
Starting
For Your Safety
Warning! Switch off, remove plug from mains
before adjusting, cleaning or if cable is cut,
damaged or entangled.
Your pressure washer requires an earth connection. The op-
erating voltage is 400 V AC, 50 Hz. Only use approved exten-
sion cables. Contact your Bosch Service Centre for details.
If you want to use an extension cable when operating your
high pressure washer, only the following cable dimensions
should be used:
– 2.5 mm
2
– max length 20 m
– 4.0 mm
2
– max length 50 m
Note: If an extension cable is used it must be earthed and con-
nected through the plug to the earth cable of your supply net-
work in accordance with prescribed safety regulations.
If in doubt contact a qualified electrician or the nearest Bosch
Service Centre.
WARNING! Inadequate extension cables can
be dangerous. Extension cable, plug and sock-
et must be of watertight construction and in-
tended for outdoor use.
Cable connections should be kept dry and off the ground.
For increased electrical safety to use a Residual Current De-
vice (RCD) with a tripping current of not more than 30 mA. Al-
ways check your RCD every time you use it.
If the supply cord is damaged, it must be replaced by a Bosch
Service Centre.
For products not sold in GB:
WARNING: For your safety, it is required that the plug at-
tached to the machine is connected with the extension cord.
The coupling of the extension cord must be protected against
splash water, be made of rubber or coated with rubber. The
extension cord must be used with a cable strain relief.
Flow rate
l/min
12.6
Maximum input pressure
MPa
1
Repulsive force at the gun to the
maximum pressure
N
33.24
Motor Insulation
Class F
Motor Protection
IPX5
Detergent tank
z
Autostop function
z
Net impedance
–
Weight according to
EPTA-Procedure 01/2003
kg
41
Protection class
/I
Serial number
See serial number (rating
plate) on pressure washer.
Dr. Egbert Schneider
Senior Vice President
Engineering
Helmut Heinzelmann
Head of Product Certification
PT/ETM9
Pressure washer
GHP 8-15 XD
Starting cycles generate brief voltage drops. Interference with other
equipment/machines may occur in case of unfavourable mains system
conditions. Malfunctions are not to be expected for system impedances
below 0,153 ohm.
Action
Figure
Delivery Scope
1
Handle Assembly
2
Mounting the hose
3
Insert dip stick for ventilation
4
Filling up detergent tank
5
Water connection
6
Clean the water strainer
7
Connecting high pressure water supply hose/
nozzle
8
Adjust water pressure
9
Adjust water jet
10
Switching on and off
11
Clean nozzle
12
OBJ_BUCH-1763-001.book Page 11 Friday, August 17, 2012 8:49 AM