Power_off, Exchange_tpdu_t0 – ACS AET65 Smart Card Reader with Fingerprint Sensor User Manual
Page 17

9.2.3.
POWER_OFF
This command powers off the card inserted in the card reader.
Command format
Header
Instruction
Data length
LEN
01 H
81 H
00 H
00 H
Response data format
Header
Status
Data length
LEN
01 H
9.2.4.
EXCHANGE_TPDU_T0
To exchange an APDU (Application Protocol Data Unit) command/response pair, between the MCU
card inserted in the AET65 and the host computer.
Command format
Header
Instruction
Data length LEN
Data
MSB
LSB
T0 TPDU
01 H A0 H
………
LEN
Length of APDU command data, N
Data
T0 TPDU to be sent to the card
Case 1: CLA INS P1 P2
Case 2: CLA INS P1 P2 Le
Case 3: CLA INS P1 P2 Lc Data
Case 4: Not supported. The driver/application should break case 4 command into
case 3 + case 2 commands.
Response data format
Header
Status
Data
length
BYTE
1
…
…
BYTE
N
SW1
SW2
LEN
01 H
BYTE x
Response data from card (if any).
SW1, SW2 Status code returned by the card.
Document Title Here
Document Title Here
Document Title Here
AET65 Reference Manual
Version 1.00
Page 17 of 19
www.acs.com.hk