beautypg.com

Fes6841 – Acnodes FES 6841 User Manual

Page 33

background image

661 Brea Canyon Rd., Suite 3

Walnut, CA 91789

tel: 909.598.7388, fax: 909.598.0218, www.acnodes.com

© Copyright 2009 Acnodes, Inc.

All rights reserved. Product description and product specifications

are subject to change without notice. For latest product information,

please visit Acnodes’ web site at www.acnodes.com.

FES6841

Fanless Embedded Controller comes with

Intel Atom N270 Processor

FES6841

Fanless Embedded Controller comes with

Intel Atom N270 Processor

(3) Exit the W83627EHG config Mode. Undesired result may occur if the config Mode is not
exited normally.

(1) Enter the W83627EHG config Mode

To enter the W83627EHG config Mode, two special I/O write operations are to be performed
during Wait for Key state. To ensure the initial state of the key-check logic, it is necessary to
perform two write operations to the Special Address port (2EH). The different enter keys are
provided to select configuration ports (2Eh/2Fh) of the next step.

(2) Modify the Data of the Registers

All configuration registers can be accessed after entering the config

Mode. Before accessing a selected register, the content of Index

07h must be changed to the LDN to which the register belongs, except some Global registers.

(3) Exit the W83627EHG config Mode

The exit key is provided to select configuration ports (2Eh/2Fh) of the next step.