14.2
Remove any dirt, mud or other
contaminants from the cable sheath for
approximately 2 meters with a clean cloth. Take
the cable seal sleeve from the kit FOSC-B/D-
CSEAL-1-NT and slide it over the cable. The non-
coated edge of the sleeve and the arrows
should be pointed to the base of the closure.
14.4
Slide the prepared cable through the
opened entry port and install the
transportation tubes described in section 5.
14.5
Align cable ring cut with the edge of
the base. Slide strength member into clamp and
tighten the nut. Cut away the excess length of
strength member.
14.6
Thoroughly clean port and cable
sheath with he cleaning tissue over a
distance of 100 mm from the edge of the port.
14.3
Prepare the cable as outlined in section 5 “Cable preparation”.