System reset, Page reset – Yamaha PSR-410 User Manual
Page 53
![background image](/manuals/24556/53/background.png)
51
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
■
Reset Procedures & Page Memory Default Settings
All PSR-410 page memory settings are retained in memory even when the power switch is turned OFF as
long as the PSR-410 is powered by batteries or an AC adapter. You can, however, restore the factory default set-
tings for all four page memories or a single specified page memory by following the procedures outlined below.
●
System Reset
Z
Press the POWER switch to turn the PSR-410 power OFF.
X
Turn the power back ON while holding both the [+] and [–] buttons.
“clr” will appear on the MULTI DISPLAY while the data is being reset.
IMPORTANT
• Executing the System Reset function will erase any existing set-
tings all page memory locations!
●
Page Reset
Z
Select the PAGE MEMORY Number You Want to Reset .....................................................................
Select the PAGE MEMORY number you want to reset (page 41).
X
Press the [MIDI BULK DUMP/PAGE COPY] Button .............................................................................
Press the [MIDI BULK DUMP/PAGE COPY] button. The “ARE YOU
SURE?” indicator will flash and the PSR-410 will ask “Are you sure?”. At
the same time “1dP”, “2dP”, “3dP”, or “4dP” will appear on the MULTI
DISPLAY, depending on the selected PAGE MEMORY number.
PAGE
MEMORY
PAGE #
MIDI BULK
DUMP/
PAGE COPY
C
Select a “cL” Display .............................................................................................................................
Use the [+] and [–] buttons or the data dial to select “1cL”, “2cL”,
“3cL”, or “4cL” (the number corresponds to the selected page number).
RESET
–
+
0
V
Press [YES] to Reset ..............................................................................................................................
Press the [YES] button to execute the page reset function, or the [NO]
button to cancel and return to the PAGE MEMORY number selection mode
(step 1, above). All settings in the selected page will be reset to their initial
values.
When the data has been reset the PSR-410 will automatically return to
the VOICE SELECT mode.
IMPORTANT
• Executing the Page Reset function will erase any existing set-
tings all selected page memory location!
ARE YOU SURE ?
NO
YES
POWER
ON / OFF
RESET
–
+