beautypg.com

Bosch AMC2 ENC-UL2 - Enclosure - Large User Manual

Page 9

background image

AEC-AMC2-UL2 - Installation manual

en

9

Bosch Sicherheitssysteme GmbH

F.01U.097.253 | V 3.2 | 2010.01

4.

Cable set A:

a.

Connect the 7-pin plug A1 to the AMC’s power supply

connector (labeled: POWER).

b.

Attach connectors A3 to the PS-interface DC and A2

to the interface labeled OK.

c.

Connect the grounding cable A4 beneath the

grounding point 3.

5.

Cable set B:

a.

Connect the plug connector B1 the second position

from the left on the power supply - labeled with BAT.

b.

Attach connector B2b (red) to the +-pin of the first

rechargeable battery.

c.

With cable C connect the --pin of the first

rechargeable battery to the +-pin of the second

rechargeable battery.

d.

Attach connector B2a (black) to the --pin of the

second rechargeable battery.

e.

Connectors B3a and B3b are not used.

6.

Cable set G:

a.

Attach connector G1 on the PS-interface labbeled

RTH.

b.

Route the cable across the temperature sensor

bracket 6 so that the temperature sensor G2 hangs

approximitely 5 cm (2 in.) above the rechargeable

batteries.

7.

Pre-assembled cable set 12:

a.

Connect the 2-pin plug 14 on the interface AC of the

power supply.

8.

Pre-assembled cable 5:

a.

Connect the loose ends of the cover tamper switch to

the 2-pin screw connector on the top of the AMC.

Position the cable in the space between the housing

and the mounting rail.

9.

Connect the main AC supply X:

a.

Connect the brown (phase) wire to terminal L1.

b.

Connect the blue (neutral) wire to terminal N.

c.

Connect the grounding cable to the housing at

position 11.

DANGER!
Remove the fuse from the three-pin connector 12 before

proceeding with the power supply connection.

Do not install the fuse before completing the installation

procedure.