3) Control sequence

(1) The command from a computer to the LCD monitor will be sent in 600 ms.
(2) The LCD monitor will send a return command 600 ms* after it has received and encoded. If the command isn’t received

correctly, the LCD monitor will not send the return command.

(3) The personal computer checks the command and confi rms if the command, which has been sent, has been executed or

not.

(4) This LCD monitor sends various codes other than return code. When having a control sequence by RS-232C, reject other

codes from personal computers side.

* : The sending time of return command may delay depending on the condition (during changing of the input signal, etc.).
Example: Turn the power ON ( ‘ ’ is for ASCII code)

Meaning

30 30 21 0D

‘0’ ‘0’ ‘!’ ‘ ’

30 30 21 0D

‘0’ ‘0’ ‘!’ ‘ ’

Sending commands

from the PC

Status code from

LCD monitor

Command for

POWER ON

Command received

(Command echoed back)

4) Operation commands

The operation commands execute the basic operation setting of this LCD monitor.
It may not operate when changing the signal:

Operation

ASCII

HEX

POWER ON

!

21h

POWER OFF

"

22h

INPUT RGB 1

_r1

5Fh 72h 31h

INPUT RGB 2

_r2

5Fh 72h 32h

INPUT RGB 3

_r3

5Fh 72h 33h

INPUT RGB 4

_r4

5Fh 72h 34h

INPUT VIDEO

_v1

5Fh 76h 31h

INPUT DVD/HD

_v2

5Fh 76h 32h

INPUT S-VIDEO** _v3

5Fh 76h 33h

INPUT RGB 5*

_r5

5Fh 72h 35h

INPUT RGB 6

_r6

5Fh 72h 36h

• POWER OFF command should be operated over 1 minute after

the power is turned on.

• POWER ON command should be operated over 1 minute after

the power is turned off.

* RGB 5 becomes usable when the optional CAT5 Rx BOX is

mounted.

** S-VIDEO is SEPARATE only

5) Read command

Host computer sends the command without Data-code to monitor.
After receiving this command, the monitor returns the command with Data-code of current status to host computer.
Example: When Host computer ask Power status of monitor, the status of monitor is powered-on.

Command from computer
30 30 76 50 0D ‘0’‘0’‘v’‘P’[enter]

Command from Monitor

Detail of command
Ask about the power status of monitor.

30 30 76 50 31 0D ‘0’‘0’‘v’‘P’‘1’[enter] Monitor is powered-on.

Structure of the Read-command

Function

Data (Receive)

Function

Data (Receive)

ON

vP

vP

1

76 50

31

OFF (stand by)

0

76 50

30

RGB-1 (HDMI)

vI

r1

76 49

72 31

RGB-2 (DVI-D)

vI

r2

76 49

72 32

RGB-3 (D-SUB)

vI

r3

76 49

72 33

RGB-6 (DISPLAY PORT)

RGB-4 (BNC)

vI

r6

76 49

72 36

RGB-5* (CAT5)

* : RGB-5 becomes usable when the optional CAT5 Rx BOX is mounted.

vI

r5

76 49

72 35

vI

r4

76 49

72 34

Video

vI

v1

76 49

76 31

DVD/HD

vI

v2

76 49

76 32

S-VIDEO

vI

v3

76 49

76 33

HIGHBRIGHT

vM
vM

p1

76 4D

70 31

STANDARD

p2

76 4D

70 32

resolution
1 ˚C
resolution
1 ˚C

74 63 31

2B 20 32 35

74 63 32

2B 20 33 31

Input

Picture mode

Temperature
of internal
monitor

Around
Main board

Around
Power PCB

POWER

(ex.) +31

(ex.) +25

tc1

tc2

ASCII

HEX