2.6 Installation location
The DHF ... C compact control is to
be installed vertically in accordance
with
A
(over-sink or under-sink) in a
closed, frost-free room, as near as possible
to the tap point (a dismantled unit is to be
stored in frost-free conditions, since resi-
dual water always remains in the unit).
2.7 Preparing for unit instal-
lation
B
Turn locking cap (3) to the left and with-
draw.
Unscrew cover securing screw and re-
move device cover.
– Detach mounting bracket (19) from the
unit.
– Thoroughly flush through the cold water
supply pipe.
– In the case of a replacement installation,
the available cold water 3-way three-way
isolating valve (
D
, 6) can if necessary be
used.
– With the help of the template (separate
this from the operating and installation
instructions), determine the position of
the cable entry (concealed connection)
and the mounting bracket (19).
G
Cut the electrical connection cable to
length and strip.
C
Secure the mounting bracket.
When replacing DHF/DHA old models
(height 370 mm), the available drilled
securing holes (20) can be used.
– Secure the unit to mounting bracket with
the screwed sleeve (14). Using the nut
on the threaded bolt (21), unevennesses
in the wall, caused for example by mis-
aligned tiles, can be compensated for
(maximum 12 mm).
2.5 Technical data
(the data on the unit rating plate are applicable)
Water connection
G ½ (external thread)
Electrical connection
3/PE ~ 400 V
1/N/PE ~
220/230 V
Max. system-impedance
Z max.
0.14
Ω
Protection mode to
EN 60529
IP 24
Typ
DHF 13 C DHF 15 C DHF 18 C DHF 21 C DHF 24 C DHF 12 C1
compact compact compact compact compact compact
control
control
control
control
control
control
Heat output
220V 230V
Partial power Stage !kW
6.6
7.5
9
10,5
12
8
8.8
Rated power Stage!!kW 13.2
15
18
21
24
12 13.2
Rated powe
Stage
!
l/min
3.0
3.0
3.9
4.4
4.9
3.0
Stage !! l/min
4.5
4.5
5.9
6.4
7.6
4.5
Flow rate limit
l/min
6.5
6.5
7.0
7.5
8.0
6.5
Pressure loss *
bar 0.55
0.55
0.6
0.6
0.7
0.55
Flow rate
l/min
4.5
4.5
5.9
6.4
7.6
4.5
Rated capacity
0,6 l
Type of construction
Closed
Rated overpressure
1 MPa (10 bar)
Weight
4,0 kg
Protection class to
DIN EN 60335
1
Test mark
See unit rating plate
Table 3
* Pressure drop values also apply to the minimum flow pressure in accordance with
DIN 44851 / Flow rate for heating from 10 °C to 55 °C (
∆ ϑ
45 K). A pressure drop of
0.1 MPa is recommended for pipe network dimensioning, in line with DIN 1988 Part 3,
Table 4.
Heating element
Copper tubular heating element
Cold water inlet
≤
20 °C
Use in waters
Total alkaline earths
≤
2.5 mol/m³
Overall hardness (earlier unit)
≤
14 °d
Hardness range (earlier unit)
Inclusive of 2 (medium hard)