Installation installation – STIEBEL ELTRON SHW ... S с 06.05.2013 User Manual
Page 21
www.stiebel-eltron.com
SHW S |
21
EN
GL
ISH
InStallatIOn
Installation
installation
f
f Fit the cylinder casing.
f
f Fit the cable grommet and control panel cover.
f
f Push on the temperature selector.
f
f If you use the "DHW circulation" connection to install a DHW
circulation line, you need to cut an opening in the cylinder
casing near the connection (indentation in the foam) for the
DHW circulation line.
f
f Remove the thermal insulation near the connection.
f
f Route the DHW circulation line through the aperture in the
cylinder casing and fit the DHW circulation line.
f
f Insulate the "DHW circulation" connection.
f
f Insert the supplied adaptor with flat gasket and an extension.
f
f Cover the hole in the cylinder casing with the adhesive rose
supplied.
f
f Fit the cover and the plinth trim of the cylinder casing.
10.2 thermometer
26
�0
2�
09
�0
06
2
f
f Insert the thermometer as far as it will go and align it.
10.3 signal anode
!
Material damage
The appliance must not be operated without a consump-
tion indicator or with a damaged one, otherwise water
will leak out once the anode is depleted.
26
�0
2�
09
�0
06
3
1
2
1 Transport protection
2 Signal anode with consumption indicator
f
f Remove the transport protection.
f
f Check the consumption indicator for transport damage.
10.4 water connection and safety assembly
10.4.1 safety instructions
Note
Carry out all water connection and installation work in
accordance with regulations.
!
Material damage
When using plastic pipework, observe chapter "Specifi-
cation / Fault conditions".
!
Material damage
Operate the appliance only with pressure-tested taps.
cold water line
Galvanised steel, stainless steel, copper and plastic are approved
materials.
A safety valve is required.
dHw line
Stainless steel, copper and plastic pipework are approved ma-
terials.