5 • cleaning your vacuum cleaner, Cleaning and maintenance – ROWENTA RO54xx serie User Manual

Page 14

background image

10

EN

2 • Changing the microfilter*
(ref RS-RT3735)

Microfilters* Ref. RS-RT3735 are available from your retailer
or from Approved Service Centres.

Open the cover of your vacuum cleaner (fig.15).
Remove the Wonderbag (fig.16), and then remove the
microfilter* cartridge (fig.29) including the microfilter (16a)
and the motor protection foam (16b).
Separate the foam (16b) from the microfilter (16a) (fig.30).
Dispose of the microfilter in a dustbin (fig 31) and replace it
with a new microfilter.
Wash the motor protection foam (16b) in warm soapy water,
rinse it and leave it to dry for at least 12 hrs before returning
it to the appliance (fig 32).
When dry, reposition it above the microfilter (16a) and then
replace the microfilter* cartridge (16) in its compartment
(fig.33).
Replace the Wonderbag (fig.20).
Check that the microfilter* cartridge is correctly positioned
before closing the cover.

3 • Changing the (H)EPA* filter

cartridge (ref. ZR 0048 01)* (for

appliances fitted with a Wonderbag*)

(H)EPA* filter cartridges ref. ZR 0048 01* are available from
your retailer or from Approved Service Centres.

Open the cover of your vacuum cleaner (fig.15). Remove the
bag support from the bag compartment (fig.16), then remove

the (H)EPA* filter cartridge (fig.34) and dispose of the cartridge
in a dustbin (fig.35).
Place the new (H)EPA* filter cartridge (ref. ZR 0048 01*) in its
compartment (fig.36).
Return the bag support to the compartment (fig.20). Check
that the (H)EPA* filter cartridge is correctly positioned before
closing the cover.

4 • Cleaning the HEPA* filter

cartridge (ref. RS-RT3734*) (for

appliances fitted with a textile bag*)

(H)EPA* filter cartridges ref. RS-RT3734* are available from
your retailer or from Approved Service Centres.

Open the cover of your vacuum cleaner (fig.15). Remove the
bag support from the compartment (fig 21), then remove the
(H)EPA* filter cartridge (fig.37).
Tap the (H)EPA* filter cartridge over a dustbin (fig.38).
Wash it with fresh water and leave it to dry for at least 24 hrs.
(fig.39)
Ensure that the (H)EPA* filter cartridge is completely dry
before replacing in the appliance.
Replace the (H)EPA* filter cartridge in its compartment (fig.40).
Replace the bag support with the textile bag* in the bag
compartment (fig 29)
Check that the (H)EPA* filter cartridge is correctly positioned
before closing the cover.

5 • Cleaning your vacuum cleaner

Wipe the vacuum cleaner and the accessories with a soft
cloth.
Do not use strong, detergent or abrasive cleaning products.

IMPORTANT: never operate the vacuum cleaner
without a filter cartridge.
To avoid the above, your appliance is equipped with
a security system to detect the presence of filter
cartridges (the cover cannot be closed unless you
have installed a filter cartridge).

IMPORTANT: Replace the microfilter every six bag
changes.

IMPORTANT: Replace the filtration system once a
year.

CAUTION! This cleaning process is solely for the
(H)EPA* filter cartridge adapted for use with the
textile bags.

IMPORTANT: Never operate the vacuum cleaner
without a filter cartridge.
To avoid the above, your appliance is equipped with
a security system to detect the presence of filter
cartridges (the cover cannot be closed unless you
have inserted a filter cartridge).

*Depending on model: equipment specific
to certain models or optional accessories.

CLEANING AND MAINTENANCE