The relevant national accident prevention regulations are to be ob-
served when commissioning, operating and servicing the vacuum.
The vacuum must always be used in conjunction with suitable
equipment.
SPECIFIED CONDITIONS OF USE
The vacuum should be set up so that the intake and exhaust air of
the motor has good circulation, and so that the vacuum does not
wander, e.g. due to vibration. Keep the air vents on the housing
unblocked and clean at all times. The vacuum must not be operated
in a closed cabinet unless the cabinet is sufficiently cooled and ven-
tilated. Please pay attention to the protection class of the device!
START-UP
Connect the suction hose to the designated connector. Please make
sure that the suction hose used can withstand temperatures above
80 °C.
Connect the mains cable.
Turn on the device at the main switch.
WARNING! Read all safety warnings and all instruc-
tions, including those given in the accompanying brochure.
Failure to follow the warnings and instructions may result in
electric shock, fire and/or serious injury. Save all warnings and
instructions for future reference.
SAFETY INSTRUCTIONS
First check whether the mains voltage corresponds to the voltage
given on the power rating plate of the vacuum.
The vacuum should be plugged into approved earthed wall sockets
only. It is forbidden to disconnect the protective ground contact.
Regularly check the connecting lead and any extension cable for
damage.
Check the hose line for damage, use proper suction hoses, tempera-
ture resistance of at least 80°C.
Please note that electrical devices must be repaired, serviced and
examined by electricians only in accordance with the national
regulations (e.g. in compliance with VBG 4), since improper repairs
can pose significant hazards to the user.
Use original replacement parts only.
No responsibility is accepted for damage incurred as a result of
disregarding the operating instructions, using the device for a use
other than the intended use, and as a result of improper repairs and
utilization.
The intended use is governed by the national work safety regulati-
ons (e.g. Appliance/Equipment Safety Law).
TECHNICAL DATA
Vacuum pump
VP 6
(110 V)
VP 6
(220-240 V)
Production code
4108 90 01...
... 000001-999999
4118 61 01...
... 000001-999999
Frequency
60 Hz
50-60 Hz
Connecting lead
400 W
250 W
No-load speed
3400 U/min
3400 U/min
Fuse
2 AT
2 AT
Final vacuum
-850 mbar
-850 mbar
Delivery rate
6 m
3
/h
100 l/min
6 m
3
/h
100 l/min
Dimensions(LxWxH)
325 x 210 x 280 mm 365 x 230 x 268 mm
Ambient temperature
-10°C – +40°C
-10°C – +40°C
Compressed air connection
IG 3/8 “
IG 3/8 “
Weight according EPTA-Procedure 01/2003
12 kg
12 kg
Motor
Protection category I (protective earthing), Protection Class IP 54
thermal overload protection
Noise information
Typically, the A-weighted noise levels of the tool are:
Sound pressure level (K=3dB(A))
Wear ear protectors!
The noise level when working can exceed 80 dB (A).
78 dB (A)
78 dB (A)