Installation manual with technical data, 0 relationship to the authorities, 0 technical data – Jotul F500 User Manual
Page 11: English, Wood consumption
![background image](/manuals/232238/11/background.png)
11
Installation manual with technical data
1.0
Relationship to the authorities ...................11
2.0
Technical data ..............................................11
3.0 Installation
.................................................. 12
4.0 Service
.......................................................... 13
5.0
Optional equipment .................................. 13
Figures/ Pictures ..................................................37
General use and maintenance manual
6.0
Safety
precautions
7.0
Choice of fuel
8.0
Use
9.0
Maintenance
10.0 Operational problems - troubleshooting
ENGLISH
1.0 Relationship to the
authorities
Installation of a fireplace must be according to local codes and
regulations in each country. All local regulations, including
those which refer to national and European standards, must be
observed when installing the product.
Both an installation manual with technical data and a manual
on general use and maintenance are enclosed with the product.
The installation can only be used after it has been inspected by
a qualified inspector.
A name plate of heat-resistant material is affixed to the
product. This contains information about identification and
documentation for the product.
2.0 Technical data
Material:
Cast iron
Finish:
Black paint, enamel
Fuel:
Wood
Log length, max.:
55 cm
Flue outlet:
Top/back
Flue pipe dimension:
Ø150 mm, 177 cm
2
cross section
Approx. weight:
200 kg
Optional extras:
Connecting pipe for outdoor
ventilation, rear heat shield
Dimensions, distances etc. See fig. 1
Technical data according to EN 13240
Nominal heat output:
8,5 kW
Flue gas mass flow:
8,0 g/sec
Recommended chimney draught:
10 Pa
Efficiency: 78%@8,7
kW
CO emission (13% O
2
): 0,10%
Flue gas temperature:
285
o
C
Operational type:
Intermittent
“Intermittent combustion” here means normal use of a stove.
That is to say, if you want to continue producing heat, you add
more fuel as soon as the previous load of wood has burnt down
to embers.
Wood consumption
Jøtul F
500 has a nominal heat output of 8,5 kW. Use of
wood, with nominal heat emission: Approx. 2,7 kg/h. Another
important factor for proper fuel consumption is that the
logs are the correct size. The size of the logs should be:
Kindling:
Length: 30 - 55cm
Diameter: 2 - 5 cm
Amount per fire: 8 -10 pieces
Firewood (split logs):
Recomended length: 35 cm
Diameter: Approx. 8 - 13 cm
Intervals for adding wood: Approximately every 80 minutes
Size of the fire: 3,5 kg
Amount per load: 2 - 3 pieces
Nominal heat emission is achieved when the airvent is open
approximately 50%.
les combustibles recommandés.
Respectez les consignes d'utilisation. Utilisez uniquement
Verwenden Sie nur empfohlenen Brennstoffen.
Montage- und Bedienungsanleitung beachten.
Follow user`s instructions. Use only recommended fuels.
standard
Certificate/
The appliance can be used in a shared flue.
Minimum distance to adjacent combustible materials:
Emission of CO in combustion products
Serial no: Y-xxxx, Year: 200x
Manufacturer:
N-1602 Fredrikstad
Norway
Jøtul AS
POB 1441
Sweden
EUR
Intermittent
Nominal heat output
Norway
Country
Operational type
Fuel type
Operation range
Efficiency
Klasse II
Classification
Standard
Flue gas temperature
Room heater fired by solid fuel
Product:
Jøtul
SP Sveriges Provnings- och
221546
Forskningsinstitut AB
SP Swedish National
Testing and Research
Institute
:
Approved by
:
:
:
:
:
:
:
Minimum distance to adjacent combustible materials:
OGC
SP
EN
Serial no.
On all our products there is a label
indicating the serial number and
year. Write this number in the
place indicated in the installation
instructions.
Always quote this serial number when
contacting your retailer or Jøtul.