C monitoring – Rorke Data Galaxy HDX2 GHDX2-2430S-24F4D User Manual
Page 67
Chapter 3 Subsystem Monitoring
System Monitoring
3-11
CPU Temperature
90ºC
5ºC
Board Temperature
80ºC
5ºC
Table 3-9: Default Threshold Values
The thresholds in Table 3-9 are the default threshold values. To see how to change these
values, please refer to the firmware Operation Manual that came with your system.
3.3.2 Failed
Devices
If any of the following devices fail, the audible alarm will be triggered:
RAID controller module
Cooling modules
PSU modules
BBU modules
Hard drives
Temperature sensors
3.4. I
2
C Monitoring
The PSUs, cooling modules, temperature sensors, and disk drive failure outputs are
monitored through an I
2
C serial bus. If any of these modules fails, you will be notified
through the various methods described above.