Page 105
Bit Error Rate Tester (BERT)
Patterns Supported
EIA530
HSU
2-port
V.35
HSU
2-port
EIA530/V.35
HSU
4-port
SRU OCU-DP
2/5/10-port
DS0-DP
4-port
All 1s
Yes
Yes
Yes
Yes
Yes
No
All 0s
Yes
Yes
Yes
Yes
Yes
No
1:1
Yes Yes Yes
Yes
Yes
No
1:7
Yes Yes Yes
Yes
Yes
No
511
Yes Yes Yes
Yes
Yes
No
2047
Yes Yes Yes
Yes
Yes
No
QRSS Yes
Yes
Yes
Yes
Yes
No
BERT Direction
EIA530
HSU
2-port
V.35
HSU
2-port
EIA530/V.35
HSU
4-port
SRU OCU-DP
2/5/10-port
DS0-DP
4-port
Toward User
No
No
No
Yes
Yes
No
Toward Network
Yes
Yes
Yes
Yes
Yes
No
Statistics Gathered by BERT
EIA530
HSU
2-port
V.35
HSU
2-port
EIA530/V.35
HSU
4-port
SRU OCU-DP
2/5/10-port
DS0-DP
4-port
Bit Errors (BE)
Yes
Yes
Yes
Yes
Yes
No
Errored Seconds (ES)
Yes
Yes
Yes
Yes
Yes
No
Severely Errored Seconds (SES)
Yes
Yes
Yes
Yes
Yes
No
Consecutive Severely Errored Seconds (CSES)
Yes
Yes
Yes
Yes
Yes
No
Out of Synchronization Seconds (OSS)
Yes
Yes
Yes
Yes
Yes
No
Bit Error Rate (BER)
Yes
Yes
Yes
Yes
Yes
No
Elapsed Seconds (ELAP)
Yes
Yes
Yes
Yes
Yes
No
Systems Equipped With Cross-Connect Option
In systems equipped with Cross-Connect CPUs, the cross-connect element adds another level of testing within the
node and enhances the system’s diagnostic capabilities. The operator may also monitor and set the state of the
Transmit and Receive ABCD signaling bits of a digitized voice circuit that is cross-connected between two WANs.
Refer to Table 28 for detailed information.
Table 28—Diagnostic Capabilities of Cross-Connect Circuits
Loop Backs
Local Loop backs
Voice
Without
Singaling
Voice
With
Signaling
Single Data
DS0
(64Kbps)
Super-rate
Data
(Nx64Kbp
s)
Toward WAN1
Yes Yes Yes Yes
Toward WAN2
Yes Yes Yes Yes