CALIBRATION
PARAMETER
SELECTIONS
MEDIA POWER UP
(password
required)
This parameter establishes the action of the media
when the printer is turned ON.
Default: Calibration
Choices: Calibration - recalibrates media and ribbon
sensors by feeding labels
Feed - feeds the label to the first web
Length - determines the length of the label
by feeding labels
No Motion - media does not move
HEAD CLOSE
(password
required)
This parameter establishes the action of the media
after the printhead has been opened and then
closed.
Default: Calibration
Choices: Calibration - recalibrates media and ribbon
sensors by feeding labels
Feed - feeds the label to the first web
Length - determines the length of the label
by feeding labels
No Motion - media does not move
MANUAL CALIBRATE If the auto-calibration feature has been disabled by a
ZPL command from the host or the HEAD CLOSE
parameter is not Calibrate, you may use this
feature to calibrate the media and ribbon sensors.
Press + to enable the Calibration process.
NOTE: If the printer is configured for continuous
media, no media movement will occur during
the Calibration process.
SENSOR PROFILE
The Media and Ribbon Sensor Profile provides a
graphical representation of the Media and Ribbon
Sensor settings as an aid to the Service Technician if
problems with inter-label gap sensing occur.
Press + to enable the Sensor Profile printout.
WEB S.
THESE SETTINGS SHOULD ONLY BE CHANGED
BY AN AUTHORIZED SERVICE TECHNICIAN.
(A password is required)
Refer to the Z Series Maintenance Manual for
additional information about these settings.
MEDIA S.
RIBBON S.
MEDIA LED
RIBBON LED
Continued on the following page.