Grill, Second oven, Main oven – Zanussi ZCG7551 User Manual
Page 36: General, Gas category countries of destination
36
Grill
Natural Gas
L.P. Gas
Heat Input
2.7kW (9215 Btu/h)
2.45kW (176.5g/h)
Injector marking
121
078
Second oven
Natural Gas
L.P. Gas
Heat input
2.4kW (8189 Btu/h)
2.4kW (172.4 g/h)
Injector marking
108
078
Dual control bypass
Fixed internal
Fixed internal
Main Oven
Heat input
2.4kW (8189 Btu/h)
2.4kW (172.4g/h)
Injector marking
108
078
Thermostat bypass marking
069
078
General
Ignition
(H.T. Spark)
Spark gap
3-4mm
Gas category countries of destination
CAT. I
2H
GB
CAT. I
3+
GB
This appliance complies with: European Council Directives Low voltage Directive
73/23/EEC, Gas Directive 90/396/EEC EMC Directive 89/336/EEC, CE Marking
Directive 93/68/EEC
.
See also other documents in the category Zanussi Radio:
- KCGV1200 (5 pages)
- U31302 ZWF 16581 (36 pages)
- ZKF641H (16 pages)
- KCEFE8002 (6 pages)
- ZBG 501 W (8 pages)
- SCFE700 (2 pages)
- NCFG1210C (3 pages)
- ZGA 75 B (22 pages)
- KCGV800 (5 pages)
- ZGF982C (16 pages)
- GAS HOB (16 pages)
- ZKG6020 (40 pages)
- ZCG 611 (24 pages)
- 200157 (3 pages)
- 200109 (2 pages)
- ZHQ 575 (60 pages)
- ZCM 5200 (18 pages)
- ZEA 85 (16 pages)
- ZCM ID (56 pages)
- U30356 ZKC6010 (32 pages)
- ZCM 650 ZCM 651 (36 pages)
- ZCM 631 (24 pages)
- ZKT 651 D (28 pages)
- 200144 (3 pages)
- ZDM 869 (31 pages)
- ZKT 641 H (28 pages)
- ZDF 290 (36 pages)
- ZCM 531 GB (28 pages)
- ZBE 602 (13 pages)
- 178025 (2 pages)
- ZKG5020 (36 pages)
- NCFGE8002 (3 pages)
- ZCM 611 (24 pages)
- ZKC6020 (40 pages)
- ZCM900X (28 pages)
- Professional SCFGG 700 (2 pages)
- NCFG1211 (3 pages)
- 285743 (2 pages)
- ZCG7550 (56 pages)
- ZGG 782 (20 pages)
- ZGF 982 (20 pages)
- ZCM930X (32 pages)
- Range Cookers (9 pages)
- ZKL64 X (20 pages)